Precautions for the use of Dewar bottles- 450L Liquid Oxygen Industrial and Medical Use Dewar Tank

Precautions for the use of Dewar bottles Factory,Distributor

1、When engaged in any work with deep cold liquid, you must wear protective equipment to prevent frostbite.
2、In the operation of liquid oxygen, the opening and closing of the valve should be done slowly, sudden opening and closing, the oxygen flow will make any pollution within this system catch fire.
3、All liquid vapors except liquid oxygen can asphyxiate people.
4、When using liquid it is recommended that the pressure in the cylinder should be reduced as much as possible.
5、The operation must ensure that the cylinder is upright, moreover, should avoid tipping over, and never roll the cylinder horizontally.
6、The storage, vaporization, filling and use of liquid oxygen are strictly prohibited within 5m of the surrounding area, and all sources of fire should be eliminated, and there should be obvious signs of no fire.
7, liquid oxygen storage, vaporization, filling, use of the place around at least 5m is not allowed to have to low places (such as basements, pits, wells, ditches) of the opening; ditch entrance must have a liquid weir.
8、Operators in filling or handling liquid oxygen, shall not wear grease stained work clothes and personal protective equipment, where the grease stained clothes and protective equipment must be replaced.

Vertical liquid oxygen dewar

450L Liquid Oxygen Industrial and Medical Use Dewar Tank

Dewar Cylinder Main Technical Parameters: Full Volume: 80L/100L/175L/195L/210L/232L/410L/500L/1000L Work Pressure: 1.37MPa/2.3MPa/2.88MPa/3.45MPa Inner Tank Design Temperature: -196℃ Shell Tank Design Temperature: -20℃~+50℃ Insulation: Vacuum with Multi-layer Wrapped Stored Medium: LO2,LN2,LAr,LCO2,LNG Inner Tank Material: SS304 08 or SA240 Shell Tank Material: Q345R or SS304 08

Vertical liquid and natural gas dewar

LNG Dewar 232L

Dewar Cylinder Main Technical Parameters: Full Volume: 80L/100L/175L/195L/210L/232L/410L/500L/1000L Work Pressure: 1.37MPa/2.3MPa/2.88MPa/3.45MPa Inner Tank Design Temperature: -196℃ Shell Tank Design Temperature: -20℃~+50℃ Insulation: Vacuum with Multi-layer Wrapped Stored Medium: LO2,LN2,LAr,LCO2,LNG Inner Tank Material: SS304 08 or SA240 Shell Tank Material: Q345R or SS304 08

Precautions for the use of Dewar bottles

You May Also Like

———

Liquid Oxygen Dewar Tank

Liquid Oxygen Dewar Tank

Medical Use Medical Use Cryogenic Dewar

Medical Use Medical Use Cryogenic Dewar

LNG Cryogenic Cyl LNG Cryogenic Cylinder Dewar Bottle for Industrial

LNG Cryogenic Cyl LNG Cryogenic Cylinder Dewar Bottle for Industrial

Nitrogen Dewar Bottle

Nitrogen Dewar Bottle

Chat with Us