Cryogenic LNG Storage Tank with ASME/GB Standard

5m³ Vertical low-temperature storage tank Runfeng

5m³ Vertical low-temperature storage tank Runfeng

5m³ Vertical low-temperature storage tank Runfeng

5m³ Vertical low-temperature storage tank Runfeng

5m³ Vertical low-temperature storage tank Runfeng

5m³ Vertical low-temperature storage tank Runfeng

5m³ Vertical low-temperature storage tank Runfeng

5m³ Vertical low-temperature storage tank Runfeng

  • Cryogenic LNG Storage Tank with ASME/GB Standard

  • 5m³ Vertical low-temperature storage tank Runfeng

  • 5m³ Vertical low-temperature storage tank Runfeng

  • 5m³ Vertical low-temperature storage tank Runfeng

  • 5m³ Vertical low-temperature storage tank Runfeng

  • 5m³ Vertical low-temperature storage tank Runfeng

  • 5m³ Vertical low-temperature storage tank Runfeng

  • 5m³ Vertical low-temperature storage tank Runfeng

  • 5m³ Vertical low-temperature storage tank Runfeng

Cryogenic LNG Storage Tank with ASME/GB Standard

Cryogenic Storage Tank Main Technical Parameters:
Full Volume: 10,000L~50,000L
Work Pressure: 0.80MPa/1.60MPa/2.30MPa/3.45MPa
Filling Rate:90%
Inner Tank Design Temperature: -196℃
Shell Tank Design Temperature: -40℃~+50℃
Insulation: Vacuum with Multi-layer Wrapped
Stored Medium: LNGInner Tank Material: SS304 08 or SA240
Shell Tank Material: Q345R or SS304 08

Product Description

Brief introduction:

This series of cryogenic storage tank is a superinsulated multi-layer storage tank, the inner vessel material is stainless steel SS30408, the outer vessel material is Q34SR or SS30408, can also be customized according to customers' requirements. It is mainly used for storing NG in liquid state. The product is widely used in urban peak gas supply, the main source of pipeline gas supply, automobile refueling fuel, chemical industry, heating and other industries, and has been favored and praised by customers for many years. praised by customers for many years.

Main Features:

The cryogenic LNG storage tank is equipped with liquid inlet pipelines at the top and bottom to realize the unloading and filling of differential pressure and cryogenic liquid pump. A double safety valve (or bursting disc) is set to discharge in case of overpressure to protect the safety of the inner container. Vacuumize and measure the vacuum pipeline, ensure the insulation performance of the interlayer, and the explosion-proof device of the shell can discharge gas in case of leakage of the inner container to avoid serious damage and danger. It has the advantages of large reserves, low evaporation rate, safety and reliability.

Via Youtube

LNG Storage Tank Main Technical Parameters:

Full Volume: 10,000L~50,000L

Work Pressure: 0.80MPa/1.60MPa/2.30MPa/3.45MPa

Filling Rate:90%
Inner Tank Design Temperature: -196

Shell Tank Design Temperature: -40℃~+50℃
Insulation: Vacuum with Multi-layer Wrapped
Stored Medium: LNGInner Tank Material: SS304 08 or SA240
Shell Tank Material: Q345R or SS304 08

Qualification Certification:

ASME VIII DIV.1, CE PED/TPED, Russia EAC, China GB, ISO9001:2015, ISO13485:2016, ISO14001:2015, ISO45001:2018

Cryogenic LNG Storage Tank with ASME/GB StandardProduction Information:

LNG cryogenic storage tank technical information sheet
Geometric
Volume
Geometric
Volume
Work Pressure
(MPa)
Liquid Gases Weight
(kg)
Tare Weight
(kg)
Inner vessel Outer vessel Overall Dimensions
(mm)
Vertical 10 ≤0.80 3829 4012 SS30408 SS30408/Q345R 5800*2112*2196
≤1.60 4112
≤2.30 4527
≤3.45 5360
20 ≤0.80 7916 7441 SS30408 SS30408/Q345R 10320*2196*2196
≤1.60 7921
≤2.30 8696
≤3.45 10251
50 ≤0.80 20235 14221 SS30408 SS30408/Q345R 5975*2135*2077
≤1.60 16860
Horizontal 10 ≤0.80 4043 4112 SS30408 SS30408/Q345R 6080*2362*2200
≤1.60 4203
≤2.30 4679
≤3.45 5634
20 ≤0.80 7915 5238 SS30408 SS30408/Q345R 10495*2362*2200
≤1.60 5329
≤2.30 6182
≤3.45 7894
50 ≤0.80 20235 16396 SS30408 SS30408/Q345R 11200*3200*3500
≤1.59 19587
Note: The above technical parameters may be changed without prior notice due to modification and development. If there is any change, please refer to the confirmed drawing.

 

The structure of the Cryogenic Storage Tank

The storage tank and supercharger consist of integrated components that allow the supply of liquid or gas without the need for external power, ensuring the purity of the discharged liquid or gas. Additionally, they are equipped with a pressure conditioning installation, enabling users to adjust the conditioning valve (T) to achieve the desired pressure for liquid discharge. This ensures stable pressure and convenient operation. The storage tank also features a liquid filling joint for tank cars, facilitating the transfer of liquid to vaporizers and tank cars.

Cryogenic LNG Storage Tank with ASME/GB Standard

The tank is equipped with top and bottom liquid inlet pipelines, which can realize pressure difference and low temperature liquid pump unloading and filling;

The liquid outlet of the storage tank can supply gas directly or enter the cryogenic pump for external gas supply;

The storage tank is equipped with gas-phase pipelines, which can realize gas discharge, safe release, pressurization and gas return after pumping;

The storage tank is equipped with an overflow pipeline to avoid overfilling when unloading and filling;

The storage tank is equipped with double safety valves (or rupture discs) to discharge when overpressure to protect the safety of the inner container;

The storage tank is equipped with a pressure gauge to display the internal pressure in real time, which should be checked regularly according to regulations;

The storage tank is equipped with a liquid level meter to display the internal medium stock, which is used for reference and not for measurement;

The tank is equipped with vacuumizing and measuring vacuum pipelines to ensure the insulation performance of interlayer;

The tank is equipped with shell explosion-proof device to discharge gas in case of leakage of inner container to avoid serious damage and danger;

The interlayer of storage tank is high vacuum multi-layer winding insulation, which has small volume, good insulation effect.

Note: the parameters of safety valve shall not be changed at will and shall be calibrated regularly, otherwise it will cause safety accidents.

Production Process:

The circumferential welds of tanks are overlapped, and the longitudinal welds are butt welded. The ring plates are arranged alternately, taking the odd number to make the end cap diameter the same. Our products adopt high vacuum multi-layer winding technology. Better thermal insulation performance and longer vacuum service life.

3-5m ³ Stainless steel Ansuda 3-5m ³ Stainless steel Ansuda 3-5m ³ Stainless steel Ansuda

Sheet metal rolling

S304 tank welding

Head welding

3-5m ³ Stainless steel Ansuda 3-5m ³ Stainless steel Ansuda 3-5m ³ Stainless steel Ansuda

Internal piping design

Pipe assembly

Finished product inspection

Advantages:

Horizontal Cryogenic Tanks for LNG Storage provide secure, safe and cost-efficient solutions for storing large volumes of liquid natural gas (LNG). LNG is stored as a cryogenic liquid at temperatures as low as -163°C. Horizontal tanks are widely used in LNG storage applications because they offer better pressure control and a lower center of gravity than vertical tanks, resulting in increased stability and safety.

Horizontal tanks can be tailored to the specific application and site conditions, allowing customers to optimize their storage capabilities. These tanks are available in a range of sizes and can be used for both short-term and long-term storage. The typical capacities of these tanks range from 50,000-250,000 gallons.

Horizontal tanks are designed with double-walled, vacuum-insulated walls, creating a safe and secure environment for the stored LNG. The primary tank is constructed from high-grade pressure vessel steel, while the inner tank is made of stainless steel. Both tanks are surrounded by a multi-layered insulation system, reducing loss to the environment and allowing for efficient operation.

Horizontal tanks feature specialized safety systems and are designed to meet all relevant global requirements. These tanks include high integrity pressure protection systems, flame arrestors, pressure relief valve, and other safety features to minimize the risk of spillage or explosion.

Horizontal tanks are also extremely durable. The exterior of the tanks are typically coated with a corrosion-resistant paint in order to prevent the tank from developing any structural damage over time. In addition, these tanks are designed to last for decades, ensuring reliable long-term storage for businesses.

Installing horizontal tanks for LNG storage offers companies several advantages. Installation requires minimal site preparation, with only a single access platform needed to set up the tank, a great cost-saving measure. Additionally, horizontal tanks require less space, allowing businesses to optimize the site area. Horizontal tanks also require minimal maintenance, making it easy to operate and monitor the stored LNG levels.

Overall, horizontal tanks for LNG storage provide businesses with Cost-efficient, secure and safe solutions for the long-term storage of large volumes of LNG. By capitalizing on their reduced installation time and space requirements, horizontal tanks allow companies to utilize their available space more efficiently. Moreover, these tanks are designed with multiple safety features and enhanced durability, ensuring businesses enjoy years of reliable operation.